Product Description
Membrane Dryer is a highly efficient equipment mainly used for the effective removal of maximum contaminants from a desired compressed air system. It also helps in decreasing the relative humidity and dew point at the same time. Membrane Dryer is equipped with four stage filtration system which delivers the progressively impressing results. It automatically cleans itself by using the phenomenon of reverse osmosis. It removes the remaining moisture back into the environment. It is extremely durable and maintenance free. This product is available in various ranges as per requirements at cost efficient rates.
WE MAINLY DEAL IN HYDERABAD & TELANGANA
Specification of Dryers :
Dew Point (PDP) deg C | 15 | 3 | -20 | -40 | Recommended | Filters |
Dewpoint Atmospheric Deg C | -15 | -26 | -40 | -70 | Particulate | Coalesing |
Purge Loss | 10% | 14% | 21% | 29% | filter | filter |
cfm | ||||||
TMD-3 | 3.5 | 2.5 | 1.7 | 1.2 | | |
TMD-5 | 5 | 3.5 | 2.5 | 1.8 | G-24 X IA | G-24 Y IA |
TMD-10 | 10.5 | 7.5 | 5 | 3.5 | | |
TMD-20 | 21 | 15 | 10 | 7 | | |
TMD-30 | 28 | 20 | 13 | 10 | G-100 X IA | G-100 Y IA |
TMD-45 | 48 | 34 | 22 | 16 | | |
TMD-60 | 60 | 42 | 28 | 20 | | |
TMD-100 | 100 | 75 | 50 | 36 | G-250 X IA | G-250 Y IA |
Specification :
- Operating temperature 2 to 60oC
- Operating pressure 7 bar (g)
- Max operating pressure 12 bar (g)
- Particulate filter 1 m
- Coalescing filter 0.01 m
Applications :
- Medical Air
- Analytical Equipments
- Pressuring Electrical Cabinets
- Pneumatics
- Painting
- Industrial Point-of-use Application
- Ozone generation
Performance correction factors for different pressures :
4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
0.41 | 0.56 | 0.76 | 1 | 1.22 | 1.48 | 1.76 | 1.86 | 2.22 |
How to order :
- Inlet flow 20 Cfm
- Working pressure 5kg/cm2
- Refering table Factor Pi = 0.56
- Dryer capacity Required Flow = 20
- Pi = 0.56
- Capacity required = 35 cfm
Other Products in 'Trident Air Dryers ' category
"We are dealing all the local inquiries of Hyderabad & Telangana "
![]() |
NEO TECHNIQUES
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |